If you change a raw material or adjust a concentration, but the product name, label artwork, and hazard pictograms remain unchanged, does the UFI code on the packaging still apply?
Under Annex VIII to the CLP Regulation, a formula change requires a new unique formula identifier (UFI) when a notified component is added, removed or substituted, or when a concentration moves beyond the limits tied to the original poison centre notification (PCN). Other changes, such as a new trade name or a new packaging type, call for an updated notification but not a new UFI code.
Why it matters
The UFI enables poison centres to identify the product’s composition during emergencies. If the code refers to an outdated formula, incorrect advice may be given.
What a UFI code identifies
The UFI code, sometimes called the UFI number, is a 16-character alphanumeric identifier printed with the prefix “UFI:”. It links a mixture on the EU or EEA market to the composition information submitted for emergency health response.
Annex VIII applies to mixtures classified for health or physical hazards. A mixture classified only for environmental hazards is outside the mandatory scope, and so are mixtures classified only as gases under pressure or only as explosives.
A UFI identifies a composition, not a product name. One composition sold under multiple trade names can use the same UFI if each trade name is included in the notification. The reverse is not permitted. In January 2025, ECHA reminded companies that reusing a UFI for mixtures with different compositions is prohibited. ECHA outlines the one UFI, one composition principle in its poison centre guidance.
Three formula changes that require a new UFI
1. A component is added, removed or replaced
If a component required in the notification is added, removed, or substituted, the notified formulation no longer matches the product on the market. This applies even if the finished product retains the same classification. Unchanged pictograms or trade names do not justify continuing to use the same UFI.
If the reformulation could affect hazard classification, assess this separately. Our guide to SCLs and M-factors in CLP mixture classification explains when small changes in concentration alter classification.
2. A concentration moves beyond the permitted variation
Annex VIII permits limited changes in concentration without requiring a new UFI. The criteria depend on whether the original PCN reported the component as an exact concentration or a range. Both scenarios are detailed below. These are not general reformulation allowances; the mixture must still meet classification and notification requirements.
3. A purchased mixture-in-mixture changes composition
Many formulations include a mixture-in-mixture (MiM), such as an additive package or fragrance blend. If the supplier changes the MiM composition, evaluate the impact on your final mixture as you would for your own changes.
A new UFI on the supplier’s product does not necessarily indicate a composition change. Suppliers may assign multiple UFIs to the same composition for commercial reasons. Confirm any changes with the supplier before updating your own identifier, and check if your notification should refer to the new MiM UFI. Our supplier SDS revision checklist addresses additional downstream checks.
How the UFI concentration limits work under Annex VIII
For a component originally notified at an exact concentration, ECHA’s concentration-change guidance specifies the permitted variation. The percentages are relative to the notified value, not percentage points.
| Originally notified exact concentration | Permitted variation | Example: UFI unchanged within |
|---|---|---|
| More than 25% to 100% | ±5% | 72% notified: 68.4% to 75.6% |
| More than 10% to 25% | ±10% | 22% notified: 19.8% to 24.2% |
| More than 2.5% to 10% | ±20% | 5% notified: 4.0% to 6.0% |
| 2.5% or less | ±30% | 1% notified: 0.7% to 1.3% |
Each row is a separate hypothetical component, not a four-component recipe.
For example, if a component is notified at exactly 22%, the ±10% allowance equals 2.2 percentage points, so the UFI remains valid from 19.8% to 24.2%. A change to 23% is within the limit, but 24.5% exceeds it and requires a new UFI and submission update.
Variation is measured against the initial notified concentration. Multiple small adjustments should be compared cumulatively to the original value, not treated as separate resets.
What if the original notification used a concentration range?
This test is simpler: compare the revised concentration to the original submission range. If it remains within the range, the UFI stays. If it falls outside, a new UFI and submission update are required.
Suppose a component was notified as 19.9% to 22.9%. A revised value of 22.1% is inside the declared range. A revised value of 23.5% is not.
Note two cautions: Annex VIII sets the range width based on the component’s hazards, so ranges cannot be expanded retroactively to accommodate changes. Additionally, standard formulas, interchangeable component groups, and generic component identifiers have specific conditions. Confirm which submission method was used before applying either test.
A PCN update does not always mean a new UFI
The UFI decision and the notification decision are related but distinct. ECHA’s instructions on keeping notifications up to date require submissions to reflect the product currently on the market. Changes unrelated to composition may require an update, even if the UFI remains valid.
| Change | UFI | What to update |
|---|---|---|
| New trade name, same mixture | Existing UFI can stay | Add the trade name to the PCN. |
| New packaging type, same mixture | Existing UFI can stay | Update packaging details in the PCN and review affected labels. |
| New toxicological information, same mixture | No new UFI on its own | Update the PCN and review the SDS. |
| Changed classification, same composition | No new UFI on its own | Update the PCN, the CLP label and the SDS. |
| New, removed or replaced component, or a concentration outside the limits | New UFI required | Generate a new UFI, submit the update and change the label. |
Under Annex VIII, the update has to be submitted before the changed mixture is placed on the market.
A revised SDS does not constitute a revised notification. The SDS informs users about hazards and handling, while the PCN provides poison centres with composition and emergency response details. Assess formula changes against both records, but an SDS revision alone does not determine if a new UFI is required.
Note that the revised CLP Regulation, (EU) 2024/2865, clarifies distributors’ poison centre obligations from January 1, 2027. Distributors who rebrand or relabel your mixture must ensure all trade names and markets are included in a valid notification.
A formula-change workflow for the product steward
Before a revised mixture is released to the EU or EEA market:
Confirm the mixture and its markets fall within Annex VIII.
Compare the revised bill of materials to the exact composition associated with the current UFI, including any MiMs.
For each concentration change, review the original PCN to determine if the component was notified as an exact value or a range, and apply the appropriate test.
Separate composition changes from other updates, such as a new trade name or packaging type.
If a new UFI is required, generate it with a new formulation number and submit the update to ensure the old and new submissions remain linked.
Before supplying the product, confirm that the notified UFI, label, SDS (where applicable), and notified markets are consistent.
Do not print a UFI that has not been notified. The code is only meaningful to a poison centre once it is included in a valid submission.
If you manufacture outside the EU
The duty to notify lies with the EU importer or downstream user, not the non-EU manufacturer. However, the formula change still starts with you. Your importer cannot make UFI decisions without knowing what has changed, so inform them before shipping the revised product. Some non-EU suppliers arrange for composition submission through an EU-based entity to avoid disclosing it to the importer. For differences in documentation by market, see Same Formula, Different SDS.
Frequently asked questions
What is a UFI code?
A UFI code is the 16-character unique formula identifier required on hazardous mixtures placed on the EU and EEA market. It links the product to the composition held by poison centres.
Does every formulation adjustment require a new UFI?
No. A concentration change within Annex VIII limits allows you to keep the existing UFI. Adding, removing, or replacing a notified component requires a new UFI.
Can a new trade name use the existing UFI?
Yes, if the composition is unchanged. The new trade name still has to be added to the notification.
Is a new UFI required when a raw-material supplier changes its UFI?
Not automatically. Determine whether the composition of the supplied mixture has changed. A new code on an unchanged composition does not require a new UFI for your finished mixture, but your notification may need to reference the supplier’s new UFI.
Where should the UFI appear?
On the label, or on the inner packaging next to the other label elements. For unpackaged mixtures and mixtures supplied for use at industrial sites, it can be given in the SDS, in Section 1.1.
Is a UFI required in Great Britain?
No. Annex VIII does not apply in Great Britain, so GB CLP does not require a UFI. Northern Ireland follows EU CLP.
Keep the UFI, the PCN and the SDS tied to one formulation record
The practical approach is to treat each formulation revision as a single change event with five possible outcomes: a UFI decision, a PCN action, a classification review, a label revision, and an SDS update. This ensures a new formula is not released under an outdated identifier.
For teams managing EU documents alongside those for other regions, Valenc’s guide to EU REACH and CLP SDS requirements details the necessary SDS content. The SDS authoring page explains how the classification record informs each regional document. The regulatory decision remains with the reviewer and should be documented before publishing any revised document.
See your EU SDSs and CLP labels built from one classification record.