SDS Section 10 addresses stability and reactivity. It specifies whether the product is stable, conditions that may cause a reaction, incompatible materials, and hazardous substances that may form during reactions or decomposition.
A product may remain stable in a sealed drum but react dangerously if heated, contaminated, or mixed with incompatible materials. Section 10 of the SDS must clarify these distinctions.
OSHA’s mandatory SDS requirements in Appendix D specify six required entries for Section 10. The key is to ensure these entries accurately describe the product and are consistent with the rest of the document, not simply to fill each heading.
The six Section 10 entries answer different questions
Each OSHA heading serves a distinct purpose. Using identical statements for all six entries obscures the differences between stability, reactions, and decomposition.
| Required entry | What it should explain |
|---|---|
| 10.1 Reactivity | How the product can react, based on product data or reliable data for the chemical family. |
| 10.2 Chemical stability | Whether it stays stable under the stated storage and handling conditions, and whether a stabilizer or a change in appearance matters. |
| 10.3 Possibility of hazardous reactions | Whether normal processes or foreseeable emergencies could produce heat, pressure, fire, gas, hazardous polymerization or another hazardous condition. |
| 10.4 Conditions to avoid | The triggers, such as heat, light, moisture, static discharge, shock, vibration or contamination. |
| 10.5 Incompatible materials | The specific substances or material classes that react with the product in a hazardous way. |
| 10.6 Hazardous decomposition products | The hazardous substances known or reasonably expected to form when the product decomposes in use, in storage or on heating. |
OSHA designates these entries as (a) through (f). While 10.1 to 10.6 numbering is not required in the U.S., it is common in international SDS formats and can aid the authoring process.
“Stable under normal conditions” needs a defined context
A stability statement is meaningful only when the evaluated conditions are specified. Clarify whether the formulation is stable in its intended container, across the stated temperature range, for the expected storage period, and in contact with its packaging. Indicate if stability depends on an inhibitor or stabilizer.
Supporting data may include formulation testing, supplier technical information, or reliable studies of the chemical family. A raw-material SDS does not determine the stability of the finished mixture, especially after blending or concentration changes.
For temperature-sensitive products, stating “stable under normal conditions” without specifying a temperature range or handling limits leaves ambiguity. If a stabilizer is essential, state this clearly. Do not assume the formulation remains unchanged indefinitely.
Hazardous reactions include foreseeable emergencies and reaction products
Two aspects of the current rule inform this entry.
First, Appendix D now words the entry as the possibility of hazardous reactions, “including those associated with foreseeable emergencies.” A spill into a drain, a fire in the next bay or water from a sprinkler head all count.
Second, 29 CFR 1910.1200 paragraph (d)(1) requires hazard classification to cover chemical reaction products associated with known or reasonably anticipated uses or applications. Appendix D gives those hazards their own line in Section 2, entry (c), separate from the classification that drives the label.
In practice, a hazard created by a foreseeable reaction is named in Section 2 and described in Section 10. It does not belong in Section 3, because the reaction product is not an ingredient of the product as supplied. OSHA took the same position on by-products in a 2016 letter of interpretation. That letter predates the 2024 update, so use the current Appendix D for the Section 2 lettering.
It is important to distinguish between stating that an interaction is dangerous and describing the specific hazard. “Avoid incompatible chemicals” does not specify consequences. If evidence shows an interaction releases a toxic gas, generates heat, or builds pressure, state this explicitly.
Our post on reaction-generated toxic gas and the SDS examines a real case. The hazard present in the shipped container may differ from hazards formed during foreseeable reactions.
Incompatible materials and conditions to avoid are not interchangeable
These two entries are often combined into a generic warning, but they should be kept separate. A condition to avoid refers to an external trigger, while an incompatible material is a specific substance.
Heat is a condition to avoid, while contact with a specific oxidizing agent is a chemical incompatibility. List water, acids, bases, oxidizers, or reducing agents only if supported by the formulation. Avoid copying broad lists from other products, as this can mislead readers.
Be as specific as the evidence permits. Name particular substances when identified by data. If reliable data support a broader material class, state the class. If a reaction has a known consequence, such as toxic vapor release or violent exotherm, describe it under hazardous reactions as well.
Check Section 10 against the rest of the SDS
Section 10 is not a standalone compliance section. Contradictions between sections can result in conflicting instructions. Review Section 10 after any formulation change or supplier SDS revision.
| Other SDS section | Cross-check before publication |
|---|---|
| Section 2: Hazard identification | Do the classified physical hazards and any reaction-product hazards agree with what Section 10 says can happen? |
| Section 5: Fire-fighting measures | Are the extinguishing media and hazardous combustion products consistent with the reactions and incompatibilities in Section 10? |
| Section 6: Accidental release | Would the recommended cleanup method put the product in contact with a listed incompatible material? |
| Section 7: Handling and storage | Do the storage conditions and incompatibilities match the Section 10 triggers and materials? |
| Section 9: Physical and chemical properties | Do the reported properties, including decomposition temperature, support the stability claims? |
Distinguish between combustion products and decomposition products. OSHA assigns hazards from fires, including hazardous combustion products, to Section 5, and hazardous decomposition products to Section 10. Both may apply to the same product but should not contradict each other. For related guidance, see our SDS Section 9 guide.
When the evidence is incomplete, say so
A missing test result does not prove a chemical is nonreactive. Appendix D requires the SDS to clearly state when no applicable information is available for a subheading. Use this statement rather than providing unsupported assurances.
A reviewer should distinguish among three situations: the condition was assessed and no hazard found, a hazard was found and must be described, or information is unavailable. Each requires a distinct statement; a single stock phrase is insufficient.
For formulated products, retain supporting evidence for each claim, including formulation revisions, supplier documents, testing or literature, applicable conditions, and reviewer decisions. If new data affect incompatibility or decomposition assessments, review all relevant SDS sections before issuing the next revision.
A six-step Section 10 review before publishing
Verify that the formulation and supplier evidence correspond to the product revision described.
Confirm all six required entries are addressed, and clearly indicate when information is unavailable.
Assess whether foreseeable uses or emergencies could generate heat, pressure, hazardous gases, or other reaction products.
Specify incompatible materials and conditions to avoid as precisely as the evidence allows.
Distinguish among reaction products, decomposition products, and combustion products, and ensure consistent wording across Sections 2, 5, and 10.
Ensure a qualified reviewer compares Sections 6, 7, and 9 with the final Section 10 before SDS approval.
Frequently asked questions
What is SDS Section 10 used for?
Section 10 outlines a product’s stability and reactivity, including how it may react, its stability, hazardous reactions, conditions to avoid, incompatible materials, and hazardous decomposition products.
Which section of the SDS lists incompatible materials?
Section 10 lists incompatible materials. Section 7 repeats those relevant for storage; both sections should be consistent.
Can an SDS simply say “stable under normal conditions”?
While the statement may be accurate, it is not sufficient on its own. The other five entries must be addressed, and specific limits such as heat sensitivity, incompatible materials, or reliance on a stabilizer must be stated.
What does hazardous polymerization mean on an SDS?
This indicates the product can polymerize uncontrollably, releasing heat or building pressure. It should be included under hazardous reactions, along with the triggering conditions and any inhibitors used.
Where do hazardous combustion products belong?
Section 5 addresses hazards from fires, including hazardous combustion products. Section 10 covers hazardous decomposition products and other reaction hazards. Review both sections when heating or burning may generate hazardous substances.
Does every formula change require a new Section 10 assessment?
Every formula change warrants a review, though it may not always alter published statements. Compare new ingredients, concentrations, and supporting evidence, and update the SDS if the previous wording no longer accurately describes the product.
Keep reaction data connected to the SDS revision
The challenge is not completing the six entries once, but maintaining alignment between reaction evidence, restrictions, and the current formulation. Ensure that supplier changes, new test results, or reformulations prompt the appropriate review.
To see where Section 10 fits in the whole document, use our 16-section SDS guide. Chemical manufacturers managing repeated revisions can also see how Valenc’s SDS authoring keeps source data, classification, review and publication on one product record.